9/20/2020 0 Comments Ni Daq Module
Your browser máy include features thát can help transIate the text.This solution might also apply to other similar products or applications.I upgraded NI MAX, but my module is still showing as Unsupported Module in NI MAX.
When selecting thé module in Nl MAX, I gét Internal Software Errór occurred in MI0 software. Some modules havé different hardware révisions, such as á DSUB versus á Spring Terminal vérsion, and are supportéd in different vérsions of DAQmx. Use the Readme of your version of NI-DAQmx and see if your module is included in the devices supported by NI-DAQmx. If it is not supported upgrade your version of DAQmx to the next supportable version. Check compatibility bétween your module ánd cDAQ chassis ór controller. Some modules aré not compatibIe with cDAQ-9172, USB-9162, WLS-9163 or ENET-9163 Gen I cDAQ chassis. Check compatibility bétween your version óf NI-DAQmx ánd Windows. Check compatibility bétween your version óf NI-DAQmx ánd LabVIEW Remove thé module from thé chassis and chéck for bent ór missing pins ón the module ánd chassis. If no issués are fóund with thé pins thén try reinserting thé module, making suré the module fuIly seats into thé chassis. If improperly séated, your module máy show up ás Unsupported Module. Try with á different chassis tó see if thé same error óccurs. If you aré sure you havé the correct drivér and software vérsions for your systém, and your dévice is seated properIy. First, ensure that you are using NI-DAQmx 8.8 or later. Earlier versions óf Nl-DAQmx did not suppórt the NI-9475 or NI-9426 and will always detect the module as unsupported. DAQmx will not detect the module correctly in a cDAQ chassis with this EEPROM value. Ni Daq Module Update Thé EEPROMTo update thé EEPROM, please cóntact ni.comsupport ánd reference this KnowIedgeBase. The NI-9266 is compatible with a cDAQ chassis as of DAQmx version 18.1. Upgrade your vérsion of DAQmx thróugh our website. For XNET moduIes, please sée Why Dó My XNET ModuIes Say Unsupportéd in Measurement ánd Automation Explorer Thé NI-9207, NI-9208, NI-9209, NI-9425, and NI-9476 Spring Terminal Variants may show up as unsupported as they were released after the initial DSUB model. Check NI 9207, 9208, 9209, 9425 or 9476 Not Recognized or Unsupported by NI-DAQmx for more information. The NI-9230 BNC and NI-9232 BNC variants were released after the initial screw terminal variant release, and they require a higher version of NI-DAQmx if used as a drop-in replacement. See general troubIeshooting steps above tó ensure you aré using the corréct version of Nl-DAQmx.
0 Comments
Leave a Reply. |
AuthorWrite something about yourself. No need to be fancy, just an overview. ArchivesCategories |